25 research outputs found

    Tunnel Magnetoresistance Sensor for Point-of-Care and Rapid Label-free Malaria Diagnosis

    Get PDF
    Traditional point-of-care malaria diagnostic platforms lack sensitivity, the devices of them are bulky and expensive. To meet the demand for malaria diagnosis in malaria-endemic countries with low-resource, a cost-effective, easy-to-use, high-sensitivity and rapid diagnostic platform is needed. Here, we report the tunnel magnetoresistance (TMR) sensor to diagnose malaria by detecting the hemozoin. The hand-held device of TMR diagnostic platform consists of a cylindrical magnet, a TMR sensor, an Analog-Front-End circuit, and a microprocessor to display the results. The test result shows that this device can detect the synthetic hemozoin in labs and have the potential to be a point-of-care diagnosis

    An improved mosquito electrocuting trap that safely reproduces epidemiologically relevant metrics of mosquito human-feeding behaviours as determined by human landing catch

    Get PDF
    Background: Reliable quantification of mosquito host—seeking behaviours is required to determine the efficacy of vector control methods. For malaria, the gold standard approach remains the risky human landing catch (HLC). Here compare the performance of an improved prototype of the mosquito electrocuting grid trap (MET) as a safer alternative with HLC for measuring malaria vector behaviour in Dar es Salaam, Tanzania. Methods: Mosquito trapping was conducted at three sites within Dar es Salaam representing a range of urbanicity over a 7-month period (December 2012–July 2013, 168 sampling nights). At each site, sampling was conducted in a block of four houses, with two houses being allocated to HLC and the other to MET on each night of study. Sampling was conducted both indoors and outdoors (from 19:00 to 06:00 each night) at all houses, with trapping method (HLC and MET) being exchanged between pairs of houses at each site using a crossover design. Results: The MET caught significantly more Anopheles gambiae sensu lato than the HLC, both indoors (RR [95 % confidence interval (CI)]) = 1.47 [1.23–1.76], P < 0.0001 and outdoors = 1.38 [1.14–1.67], P < 0.0001). The sensitivity of MET compared with HLC did not detectably change over the course of night for either An. gambiae s.l. (OR [CI]) = 1.01 [0.94–1.02], P = 0.27) or Culex spp. (OR [CI]) = 0.99 [0.99–1.0], P = 0.17) indoors and declined only slightly outdoors: An. gambiae s.l. (OR [CI]) = 0.92 [0.86–0.99], P = 0.04), and Culex spp. (OR [CI]) = 0.99 [0.98–0.99], P = 0.03). MET-based estimates of the proportions of mosquitoes caught indoors (P i ) or during sleeping hours (P fl ), as well as the proportion of human exposure to bites that would otherwise occurs indoors (π i ), were statistically indistinguishable from those based on HLC for An. gambiae s.l. (P = 0.43, 0.07 and 0.48, respectively) and Culex spp. (P = 0.76, 0.24 and 0.55, respectively). Conclusions: This improved MET prototype is highly sensitive tool that accurately quantifies epidemiologically-relevant metrics of mosquito biting densities, behaviours and human exposure distribution

    Impedimetric Detection and Electromediated Apoptosis of Vascular Smooth Muscle Using Microfabricated Biosensors for Diagnosis and Therapeutic Intervention in Cardiovascular Diseases

    Get PDF
    Cardiovascular diseases remain a significant global burden with 1‐in‐3 of all deaths attributable to the consequences of the disease. The main cause is blocked arteries which often remain undetected. Implantable medical devices (IMDs) such as stents and grafts are often used to reopen vessels but over time these too will re‐block. A vascular biosensor is developed that can report on cellularity and is amenable to being mounted on a stent or graft for remote reporting. Moreover, the device is designed to also receive currents that can induce a controlled form of cell death, apoptosis. A combined diagnostic and therapeutic biosensor would be transformational for the treatment of vascular diseases such as atherosclerosis and central line access. In this work, a cell sensing and cell apoptosing system based on the same interdigitated electrodes (IDEs) is developed. It is shown that the device is scalable and that by miniaturizing the IDEs, the detection sensitivity is increased. Apoptosis of vascular smooth muscle cells is monitored using continuous impedance measurements at a frequency of 10 kHz and rates of cell death are tracked using fluorescent dyes and live cell imaging

    Development and evaluation of mosquito-electrocuting traps as alternatives to the human landing catch technique for sampling host-seeking malaria vectors

    Get PDF
    Background The human landing catch (HLC) is the gold standard method for sampling host-seeking malaria vectors. However, the HLC is ethically questionable because it requires exposure of humans to potentially infectious mosquito bites. Methods Two exposure-free methods for sampling host-seeking mosquitoes were evaluated using electrocuting surfaces as potential replacements for HLC: (1) a previously evaluated, commercially available electrocuting grid (CA-EG) designed for killing flies, and (2) a custom-made mosquito electrocuting trap (MET) designed to kill African malaria vectors. The MET and the CA-EG were evaluated relative to the HLC in a Latin Square experiment conducted in the Kilombero Valley, Tanzania. The sampling consistency of the traps across the night and at varying mosquito densities was investigated. Estimates of the proportion of mosquitoes caught indoors (P i ), proportion of human exposure occurring indoors (π i ), and proportion of mosquitoes caught when most people are likely to be indoors (P fl ) were compared for all traps. Results Whereas the CA-EG performed poorly (<10 % of catch of HLC), sampling efficiency of the MET for sampling Anopheles funestus s.l. was indistinguishable from HLC indoors and outdoors. For Anopheles gambiae s.l., sampling sensitivity of MET was 20.9 % (95 % CI 10.3–42.2) indoors and 58.5 % (95 % CI 32.2–106.2) outdoors relative to HLC. There was no evidence of density-dependent sampling by the MET or CA-EG. Similar estimates of P i were obtained for An. gambiae s.l. and An. funestus s.l. from all trapping methods. The proportion of mosquitoes caught when people are usually indoors (P fl ) was underestimated by the CA-EG and MET for An. gambiae s.l., but similar to the HLC for An. funestus. Estimates of the proportion of human exposure occurring indoors (π i ) obtained from the CA-EG and MET were similar to the HLC for An. gambiae s.l., but overestimated for An. funestus. Conclusions The MET showed promise as an outdoor sampling tool for malaria vectors where it achieved >50 % sampling sensitivity relative to the HLC. The CA-EG had poor sampling sensitivity outdoors and inside. With further modification, the MET could provide an efficient and safer alternative to the HLC for the surveillance of mosquito vectors outdoors. Keywords: Mosquito electrocuting trap; Human landing catch; Mosquito behaviour; Vector sampling tools; Outdoor biting; Malaria; Anopheles arabiensis ; Anopheles gambiae s.l.; Anopheles funestus s.l

    Wavelength-dependent effects of artificial light at night on phytoplankton growth and community structure

    Get PDF
    Artificial light at night (ALAN) is a disruptive form of pollution, impacting physiological and behavioural processes that may scale up to population and community levels. Evidence from terrestrial habitats show that the severity and type of impact depend on the wavelength and intensity of ALAN; however, research on marine organisms is still limited. Here, we experimentally investigated the effect of different ALAN colours on marine primary producers. We tested the effect of green (525 nm), red (624 nm) and broad-spectrum white LED ALAN, compared to a dark control, on the green microalgae Tetraselmis suesica and a diatom assemblage. We show that green ALAN boosted chlorophyll production and abundance in T. suesica. All ALAN wavelengths affected assemblage biomass and diversity, with red and green ALAN having the strongest effects, leading to higher overall abundance and selective dominance of specific diatom species, some known to cause harmful algal blooms. Our findings show that green and red ALAN should be used with caution as alternative LED colours in coastal areas, where there might be a need to strike a balance between the effects of green and red light on marine primary producers with the benefit they appear to bring to other organisms

    A compact dual-band implantable antenna for wireless biotelemetry in arteriovenous grafts

    Get PDF
    Arteriovenous grafts (AVGs) are indispensable life-saving implants for chronic kidney disease (CKD) patients undergoing hemodialysis. However, AVGs will often fail due to postoperative complications such as cellular accumulation termed restenosis, blood clots, and infections, which are dominant causes of morbidity and mortality. A new generation of hemodialysis implants equipped with biosensors and multi-band antennas for wireless power and telemetry systems that can detect specific pathological parameters and report AVGs’ patency would be transformative for CKD. Our study proposes a compact dual-band implantable antenna for hemodialysis monitoring applications. It operates in 1.4 GHz and 2.45 GHz for wireless power transfer and biotelemetry purposes. The miniaturized antenna with a current size of 5 × 5 × 0.635 mm 3 exhibits wide bandwidth (300 MHz at 1.4 GHz band and 380 MHz at 2.45 GHz band), along with good impedance matching at two resonance frequencies. In addition, simulations are performed separately in a three-layer homogenous phantom and a realistic human body model. Measurements of the proposed antenna are evaluated in minced pork. The measured results of the fabricated antenna prototype are closely harmonized with the simulation ones, and the effect of different proportions of fat tissue in pork mince was analyzed, to verify the sensitivity of the antenna to the contacting medium. The specific absorption rate (SAR) and link budget calculation are also analyzed. Finally, the wireless biotelemetry function of the proposed antenna is realized and visualized by adopting a pair of nRF24L01 wireless transceivers, and sustainable and stable wireless data transmission characteristics are shown at a high data rate of 2 Mbps with up to 20 cm transmission distance

    Mosquito electrocuting traps for directly measuring biting rates and host-preferences of Anopheles arabiensis and Anopheles funestus outdoors

    Get PDF
    Background: Mosquito biting rates and host preferences are crucial determinants of human exposure to vectorborne diseases and the impact of vector control measures. The human landing catch (HLC) is a gold standard method for measuring human exposure to bites, but presents risks to participants by requiring some exposure to mosquito vectors. Mosquito electrocuting traps (METs) represent an exposure-free alternative to HLCs for measuring human exposure to malaria vectors. However, original MET prototypes were too small for measuring whole-body biting rates on humans or large animals like cattle. Here a much larger MET capable of encompassing humans or cattle was designed, and its performance was evaluated relative to both the original small MET and HLC and for quantifying malaria vector host preferences. Methods: Human landing catch, small human-baited METs (MET-SH), and large METs baited with either a human (MET-LH) or calves (MET-LC) were simultaneously used to capture wild malaria vectors outdoors in rural southern Tanzania. The four capture methods were compared in a Latin-square design over 20 nights. Malaria vector host preferences were estimated through comparison of the number of mosquitoes caught by large METs baited with either humans or cattle. Results: The MET-LH caught more than twice as many Anopheles arabiensis than either the MET-SH or HLC. It also caught higher number of Anopheles funestus sensu lato (s.l.) compared to the MET-SH or HLC. Similar numbers of An. funestus sensu stricto (s.s.) were caught in MET-LH and MET-SH collections. Catches of An. arabiensis with human or cattle-baited large METs were similar, indicating no clear preference for either host. In contrast, An. funestus s.s. exhibited a strong, but incomplete preference for humans. Conclusions: METs are a sensitive, practical tool for assessing mosquito biting rates and host preferences, and represent a safer alternative to the HLC. Additionally these fndings suggest the HLC underestimate whole-body human exposure. MET collections indicated the An. funestus s.s. population in this setting had a higher than expected attack rate on cattle, potentially making eliminating of this species more difiicult with human-targeted control measures. Supplementary vector control tools targeted at livestock may be required to effectively tackle this species

    Evaluation of mosquito electrocuting traps as a safe alternative to the human landing catch for measuring human exposure to malaria vectors in Burkina Faso

    Get PDF
    Background: Measuring human exposure to mosquito bites is a crucial component of vector-borne disease surveillance. For malaria vectors, the human landing catch (HLC) remains the gold standard for direct estimation of exposure. This method, however, is controversial since participants risk exposure to potentially infected mosquito bites. Recently an exposure-free mosquito electrocuting trap (MET) was developed to provide a safer alternative to the HLC. Early prototypes of the MET performed well in Tanzania but have yet to be tested in West Africa, where malaria vector species composition, ecology and behaviour are different. The performance of the MET relative to HLC for characterizing mosquito vector population dynamics and biting behaviour in Burkina Faso was evaluated. Methods: A longitudinal study was initiated within 12 villages in Burkina Faso in October 2016. Host-seeking mosquitoes were sampled monthly using HLC and MET collections over 14 months. Collections were made at 4 households on each night, with METs deployed inside and outside at 2 houses, and HLC inside and outside at another two. Malaria vector abundance, species composition, sporozoite rate and location of biting (indoor versus outdoor) were recorded. Results: In total, 41,800 mosquitoes were collected over 324 sampling nights, with the major malaria vector being Anopheles gambiae sensu lato (s.l.) complex. Overall the MET caught fewer An. gambiae s.l. than the HLC (mean predicted number of 0.78 versus 1.82 indoors, and 1.05 versus 2.04 outdoors). However, MET collections gave a consistent representation of seasonal dynamics in vector populations, species composition, biting behaviour (location and time) and malaria infection rates relative to HLC. As the relative performance of the MET was somewhat higher in outdoor versus indoor settings, this trapping method slightly underestimated the proportion of bites preventable by LLINs compared to the HLC (MET = 82.08%; HLC = 87.19%). Conclusions: The MET collected proportionately fewer mosquitoes than the HLC. However, estimates of An. gambiae s.l. density in METs were highly correlated with HLC. Thus, although less sensitive, the MET is a safer alternative than the HLC. Its use is recommended particularly for sampling vectors in outdoor environments where it is most sensitive

    Realtime monitoring of thrombus formation in vivo using a self-reporting vascular access graft

    Get PDF
    Background: Chronic kidney disease (CKD) affects 10% of the global population costing over a hundred billion dollars per annum and leading to increased risk of cardiovascular disease. Many patients with CKD require regular haemodialyses. Synthetic arteriovenous grafts (AVG) are increasingly used to provide rapid vascular connection for dialysis. Initially, they have excellent patency rates but are critically limited by neointimal hyperplasia at the venous anastomosis, which drives subsequent thrombosis, graft failure and death. Methods: Here, we describe a system in which electrical impedance spectroscopy sensors are incorporated circumferentially into the wall of a synthetic arteriovenous graft. This is combined with an implantable radiotelemetry system for data transmission outside the patient. The system was tested using monolayers of endothelial and smooth muscle cells as well as swine blood and clots with explanted human carotid artery plaques. Sensor testing was then performed in vitro and the device was implanted in vivo in female swine. Results: The device can wirelessly report the accumulation of biological material, both cells and blood. Differences are also detected when comparing controls with pathological atheroma. In swine differences between blockage formation in a graft were remotely obtained and wireless reported. Conclusions: Combining electrical impedance spectroscopy and an implantable radiotelemetry system enables graft surveillance. This has the potential to be used for early detection of venous stenosis and blood clot formation in real-time in vivo. In principle, the concept could apply to other cardiovascular diseases and vascular implantable devices